Burkert Type 8081 Manuale Utente Pagina 13

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 68
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 12
13
Type 8081
english
Technical data
6.3.2. General data
Pipe diameter DN15 to DN25
Type of fluid water (or neutral liquids on request)
Fluid temperature 5 to 90°C
Fluid pressure PN 16
Measuring range 0.06 to 200 l/min
Accuracy (see curves on
next page)
± (0.01 % of Full Scale* + 2% of
measured value)
1)
Repeatability 1% of measured value
Measuring element 2 ultrasound emitter-receiver cells
* Full Scale, see measuring range on the diagram of measurement accuracy.
1)
Reference conditions: fluid = water, water and ambient temperatures = 20°C
Measurement accuracy
-10
-8
-6
-4
-2
0
2
4
6
8
10
0,1 1 10 100 1000
max DN25
max DN15
max DN20
Flow rate in l/min
Max. measurement
deviation in %
Vedere la pagina 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 67 68